Projects › Data-Centre Disaster Recovery: Active/Standby Failover

Data-Centre Disaster Recovery: Active/Standby Failover

The order-management application runs in DC1, with a warm standby in DC2 on the same address (10.100.0.10), so branches never need to change anything when it fails over. Its databases replicate between DB-DC1 and DB-DC2 over a dedicated DC interconnect. Two branches and both data centres share a carrier metro-Ethernet service. All interfaces are addressed; there is no routing yet. Build it so branches use DC1, replication stays on the interconnect, and a silent loss of DC1 moves the branches to DC2 within the 5-second recovery objective.

Difficulty: expert · Time: about 75 minutes

Why it matters

Disaster recovery is judged by numbers agreed with the business: the recovery time objective. Advertising the same application prefix from both sites with the standby at a worse cost is a common way to fail over without changing DNS or clients. The catch is that over a carrier Ethernet service a dead router does not drop the link, so failure is only noticed when the routing protocol's dead timer expires: 40 seconds by default for OSPF. Meeting a 5-second objective means tuning for it and measuring it.